Common EICR Myths: What Manchester Landlords Still Get Wrong in 2026

Common EICR Myths: What Manchester Landlords Still Get Wrong in 2026

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 have been in force for over six years. Every private landlord in England is required to have a valid EICR for each tenanted property, supply a copy to the tenant and carry out any remedial work identified. Despite this, a surprising number of landlords in Manchester and across Greater Manchester continue to operate under misconceptions about what the regulations require, what an EICR actually covers and what happens when things go wrong.

These myths are not harmless. Acting on incorrect assumptions can lead to invalid certificates, enforcement action from the local authority, insurance claim rejections and — in the worst cases — serious electrical incidents that could have been prevented. This guide addresses the most persistent misconceptions we encounter when working with landlords across the region.

Myth 1: A New Build Does Not Need an EICR

This is one of the most common assumptions, and it is wrong. The regulations make no exemption for new-build properties. If you are letting a property as a private rental, it requires a valid EICR regardless of its age. A new-build property will have an Electrical Installation Certificate (EIC) issued at completion, which confirms the installation met BS 7671 at the time it was signed off. However, the EIC is not the same document as an EICR, and it does not satisfy the ongoing requirement under the 2020 regulations.

In practice, many new-build properties will pass their first EICR without issues. But the test still needs to be carried out and the report issued. We have also seen new-build properties in Manchester fail EICRs — typically because of snagging issues left unresolved by the developer, poor workmanship by subcontractors or modifications made after the original EIC was issued.

The EIC from the developer may cover you for the initial period, but you should confirm with your local authority that they accept it in place of an EICR. Most councils in Greater Manchester expect to see an EICR specifically.

Myth 2: C3 Codes Can Be Ignored

An EICR classifies observations using a coding system: C1 (danger present), C2 (potentially dangerous), C3 (improvement recommended) and FI (further investigation required). Many landlords assume that because C3 is described as a recommendation rather than a requirement, it can be safely ignored.

The regulations require landlords to complete remedial work for any observation that results in the EICR being rated as unsatisfactory — and a report is unsatisfactory if it contains C1 or C2 observations. A report that contains only C3 observations will be rated satisfactory, so in a strict legal sense, you are not required to carry out C3 work to comply with the regulations.

However, ignoring C3 codes carries risks. A C3 observation is telling you that part of your installation does not meet the current edition of BS 7671, even though it is not immediately dangerous. At the next EICR, the same issue may be reclassified as a C2 if the inspector judges that the installation has deteriorated further. More importantly, if an electrical incident occurs at the property and a subsequent investigation reveals that a known C3 deficiency contributed to the incident, you may face questions about why you chose not to address it.

The practical advice is to review each C3 observation on its merits. Some — such as the absence of RCD protection on circuits that current standards now require it — are straightforward and inexpensive to address during remedial work for C1 or C2 items. Others may genuinely be low priority. The decision should be informed, not automatic.

Myth 3: Any Electrician Can Carry Out an EICR

An EICR must be carried out by a person who is qualified and competent to inspect and test electrical installations. The regulations specify that the inspector must be a qualified person — defined as someone who holds a recognised qualification in electrical inspection and testing (such as the City and Guilds 2391 or 2394/2395) and is a member of a competent person scheme such as NICEIC, NAPIT or ELECSA.

A general electrician who is qualified to install but not to inspect and test does not meet the competence requirement. Similarly, a person who holds the inspection qualification but is not registered with a competent person scheme may not be accepted by your local authority or insurer. In Greater Manchester, councils including Salford and Oldham have specifically asked landlords for NICEIC or equivalent registration numbers when reviewing compliance documentation.

If you are unsure whether your electrician is suitably qualified, ask them to confirm their registration and their personal inspection qualification before instructing the work. Using an unqualified person does not just risk an invalid report — it means the defects in your installation may go unidentified entirely.

Myth 4: The EICR Only Needs Doing Every Ten Years

The ten-year interval is the maximum recommended period between EICRs for domestic properties under the IET guidance notes. However, the 2020 regulations require landlords to ensure that an EICR is obtained at least every five years. The five-year obligation applies to all new tenancies created since June 2020 and to all existing tenancies since April 2021.

There is a widespread misconception — particularly among landlords who have owned properties for many years — that the old ten-year guideline still applies. It does not. If your last EICR was carried out in 2021, your next one is due by 2026 at the latest. If you are relying on a report from 2016 or earlier, you are already in breach of the regulations.

The confusion is compounded by the fact that the IET guidance notes still reference ten-year maximum intervals for domestic installations as a general recommendation. For landlords, the five-year statutory requirement takes precedence. If you are managing multiple properties across Manchester, mapping your EICR dates and staggering renewals over a rolling programme is the most practical way to stay on top of the obligation.

Myth 5: A Satisfactory EICR Means the Electrics Are Perfect

A satisfactory EICR means that the installation, at the time of inspection, met the minimum standard for continued use and did not contain any defects classified as C1 or C2. It does not mean the installation is new, modern or free from all issues. A satisfactory report may still contain C3 observations and advisory notes about areas where the installation falls short of current standards but is not dangerous.

It is also important to understand that an EICR is a sample-based inspection. The inspector tests a representative sample of circuits and visually inspects accessible parts of the installation. Components that are concealed behind plasterwork, buried under flooring or otherwise inaccessible are assessed by inference rather than direct examination. A satisfactory result is a professional opinion based on the evidence available at the time — not a guarantee that nothing will go wrong.

For landlords, the practical takeaway is that a satisfactory EICR is the baseline, not the finish line. If the report includes C3 observations, consider addressing them. If the report notes that certain areas were not accessible, arrange access for the next inspection. And if the installation is approaching the end of its serviceable life, start planning for a rewire or major upgrade rather than waiting for the next EICR to return an unsatisfactory result.

Myth 6: The Tenant Can Refuse Access and Nothing Happens

Tenants do have a right to quiet enjoyment of their home, and a landlord cannot force entry for a routine EICR without following the correct process. However, the regulations place the compliance obligation on the landlord, and failure to meet that obligation — even if caused by tenant access difficulties — can result in enforcement action.

The correct approach is to give the tenant reasonable written notice (at least 24 hours, though more is advisable), explain the purpose of the inspection and offer flexible appointment times. If the tenant repeatedly refuses access despite reasonable attempts, you should document every attempt in writing and contact your local authority to explain the situation. We have a detailed guide on tenant access and landlord rights for EICR inspections.

Councils in Greater Manchester generally take a pragmatic view where a landlord can demonstrate genuine efforts to arrange access. What they will not accept is a landlord using tenant refusal as a blanket excuse for non-compliance, particularly where no evidence of access attempts exists.

Myth 7: The EICR Covers Appliances and Plug-In Equipment

An EICR tests the fixed electrical installation — the wiring, distribution boards, protective devices, socket outlets, light fittings and any permanently connected equipment. It does not test portable appliances such as kettles, toasters, extension leads, laptop chargers or any other plug-in equipment.

Portable appliance testing (PAT) is a separate process that inspects and tests individual items of portable electrical equipment. While PAT testing is not a legal requirement for domestic landlords, it is a legal requirement for equipment in commercial premises and is good practice for furnished rental properties where the landlord provides electrical appliances.

If you are providing a furnished let with appliances, the EICR alone does not confirm that those appliances are safe. You need either PAT testing or a documented visual inspection regime for the appliances, separate from the EICR. For a comparison of what each test covers, see our guide to EICR versus PAT testing.

Getting It Right

The regulations are not ambiguous, but they do require landlords to understand specific technical and legal details. The simplest way to avoid falling foul of these myths is to work with a qualified, registered electrical contractor who understands both the technical requirements of BS 7671 and the regulatory framework that applies to the private rented sector.

Call us on 0161 312 2720 to arrange your EICR or to discuss any aspect of your compliance obligations. You can also email hello@manchestercompliance.co.uk. We work with landlords across Greater Manchester — Salford, Stockport, Oldham, Tameside, Rochdale, Trafford and the city centre — and we are happy to answer questions before you book.

For a complete overview of your obligations, see our landlord electrical safety guide for 2026.

Need Help With Your Electrical Compliance?

Our NICEIC approved electricians are ready to help with EICRs, remedials, rewires and more across Manchester.

0161 706 1360
Chat with us